Product name: Airwasher air handling unit

The Airwasher air handling unit possesses all the features of an industrial air handler. In this type of air handling unit, a separate chamber with a galvanized body is provided for air washing and humidity control. The required humidity is achieved through the use of atomized water.
Product Information

The Airwasher AHU (Air Handling Unit) incorporates all the features of an industrial AHU and includes a separate chamber with a galvanized body for air washing and humidification. The desired humidity is achieved through the use of atomized water. The Airwasher AHU is used in dry and semi-dry climates and in situations where the building lacks a central cooling plant.
The Airwasher AHU utilizes an airwasher and water spray for cooling, eliminating the need for a cooling coil. However, a pre-cooling coil can be added to enhance cooling if required, and this part of the unit is integrated based on the customer's needs. For heating, warm water from a boiler is pumped through the coil (copper finned tubes) of the AHU, and a fan blows fresh air over the coils, transferring heat to the air.
This type of AHU should not be used in humid areas or places where moisture could be damaging, such as server rooms or locations where metal rusting might occur.

Technical specifications

Technical Specifications of Airwasher AHU

The frame of all air handling units (AHUs) is designed and manufactured from steel sheet appropriate for the weight of the unit, and is coated with either powder-coated or liquid paint. All components of the AHU are installed on this frame. The Airwasher AHU, designed for air conditioning, air washing, and humidification, features a galvanized body and centrifugal fans (both forward and backward) with airflow capacities ranging from 2,000 to 70,000 cubic feet per minute. It is available in classes 8, 6, and 4, and can be equipped with various types of filters and heating and cooling coils.

Technical Specifications of Class 4 Airwasher Device

Only a single row of low-flow water injection nozzles is used, so that while providing cooling, the humidity of the air increases to a lesser extent.

Class 6 earwasher technical specifications

Here is the translationWe have the same single row of water injection nozzles, but with a medium flow rate. The cooling capacity of the unit is higher compared to Class 4, and the increase in air humidity is moderate. Most air washers are designed and built based on this principle.

Class 8 airwasher technical specifications

Instead of using a single row, two rows of water spray nozzles are employed, which provides higher cooling capacity compared to the other two types but also significantly increases the relative humidity of the air. This type and Class 4 type are used only in certain specialized projects. To extend the device's lifespan, the drainage tray is covered with fiberglass. The nozzles are made of ABS with stainless steel (anti-scale) outlet nozzles.

Air washer components

Heating coil / Air filters / Sound and vibration isolators / Fans / Electric motor / Intelligent control system / Water spray and air washing chamber. After completing the design stages, including determining cooling and heating loads, air flow rate, type of filters, static pressure, and required humidity, the air handling unit can be designed and manufactured accordingly.